Inappropriate use of pharmacy bulk packages of IV contrast media increases risk of infections
September 20, 2012

Problem: Recently, the Centers for Disease Control and Prevention (CDC) reiterated its position calling for medications labeled as “single dose” or “single use” to be used for only one patient (www.cdc.gov/injectionsafety/CDCposition-SingleUseVial.html). Single-use medications typically lack antimicrobial preservatives and can become contaminated and serve as a source of pathogens when used inappropriately. With costly medications or severe drug shortages encouraging the inappropriate reuse of single-dose vials, and a national survey in which 6% of nurses admitted to always or sometimes using this unsafe practice (www.ismp.org/Newsletters/acutecare/articles/20101202.asp), hospitals may find it challenging to meet the CDC requirement. ISMP has learned of another challenge in this area with intravenous radiographic contrast media, a medication that is easy to overlook because the product is often not dispensed for individual patients from the pharmacy. 

Some clinical staff have been using pharmacy bulk packages (PBP) of contrast media as multiple-dose containers and administering doses from the same container to multiple patients throughout the day in the radiology department, cardiac catheterization lab, and cardiac surgery locations. Staff may believe the PBP of contrast media is a multiple-dose container because some manufacturers refer to it as a “multipack” (e.g., ISOVUE MULTIPACK, PROHANCE MULTIPACK). However, we are unaware of any intravenous contrast media that is packaged in a multiple-dose container in the traditional sense. PBPs of contrast media do not contain the preservatives found in most multiple-dose containers of medications that normally help to prevent contamination and the spread of infection.          

The US Pharmacopeia (USP) provides a detailed definition of a PBP, which includes but is not limited to the following crucial parameters:

  1. A PBP is a container of a sterile preparation for parenteral use that contains many single doses. The contents of PBPs are intended for use in a pharmacy admixture program and are restricted to the preparation of admixtures for infusion or, through a sterile transfer device, for the filling of empty sterile syringes.
  2. The PBP closure shall be penetrated only one time after constitution with a suitable sterile transfer device or dispensing set which allows dispensing of the contents.
  3. The PBP is to be used only in a suitable work area such as a laminar flow hood (or an equivalent clean air compounding area).
  4. PBPs, although containing more than one single dose, are exempt from the multiple-dose container volume limit of 30 mL and the requirement that they contain a substance or suitable mixture of substances to prevent the growth of microorganisms.
  5. When a container is offered as a PBP, the label shall contain or refer to information on proper techniques to assure safe use of the product and bear a statement limiting the timeframe in which the container may be used once it has been entered, provided it is held under the labeled storage conditions.

The US Food and Drug Administration (FDA) considers an aseptic area to be a suitable work area for using PBP’s. FDA defines an aseptic area as having engineering controls such as HEPA-filtered laminar air flow that meets the standards for ISO Class 5, appropriate cleaning and disinfection procedures, and periodic microbiological monitoring of the area. FDA does not regard PBPs as appropriate for use in a radiology suite unless the suite meets the criteria for a suitable work area as noted above. More information pertaining to a suitable work environment can be found in in USP General Chapter <797>.

Accordingly, package labeling for PBPs of intravenous contrast media recommends transfer of the contents in a suitable work area as defined above, penetration of the closure only one time, and immediate transfer of its contents using a suitable transfer device. However, the labeling suggests that if the content transfer cannot be accomplished immediately, it can be completed within a maximum of 4 to 10 hours (depending on the specific product) from initial closure entry as long as the PBP container is not removed from the aseptic area during the entire 4- to 10-hour period.

Confusion regarding the proper transfer of intravenous contrast media from PBPs has been perpetuated by the labeling of some radiographic contrast injectors on the market that describe use with PBPs, which is inconsistent with the PBP labeling. FDA is aware of these labeling issues and is in the process of resolving the inconsistencies in the device and drug labeling.

Another confounding factor is that some staff erroneously believe that use of a sterile transfer set, as outlined in point 2 of the USP definition of a PBP, is all that is required to meet the standards of a “suitable work area.” In these cases, hospital staff hang a PBP of intravenous contrast media with a sterile transfer set attached for the entire day in a radiology suite or other unsuitable environment. Staff then withdraw multiple, individual patient doses from the PBP with a power injector (or by hand in cardiac catheterization and surgery units) by entering the container over and over again. Such practices, which are inconsistent with FDA requirements for the proper use of PBPs, the Centers for Medicare and Medicaid Services (CMS) Conditions of Participation for Hospitals, the CDC Injection Safety Guidelines, and The Joint Commission standards, expose patients to the risk of developing a potentially life-threatening infection.

In fact, serious and fatal infections from misuse of single-use vials of contrast media were reported in the July 13, 2012, issue of Morbidity and Mortality Weekly Report (MMWR). According to the CDC, three patients in an Arizona pain management clinic who received contrast media injections from the same container during radiologic imaging were admitted to the hospital for severe methicillin-resistant Staphylococcus aureus (MRSA) infections including mediastinitis, bacterial meningitis, epidural abscess, and sepsis. Hospitalization ranged from 9 to 41 days, with additional long-term care required for one patient. A fourth patient who received contrast from the same vial was found deceased at home. The cause of death was reported as a multiple-drug overdose; however, an invasive MRSA infection from cross-contamination of the contrast media could not be ruled out. In addition to identifying improper reuse of contrast media containers intended for single-use, officials also noted that healthcare staff failed to wear facemasks during the spinal injection procedures.  

Safe Practice Recommendations: To reduce the risk of infections from contamination of intravenous contrast media, consider the following recommendations.

Pharmacy oversight. The pharmacy department should oversee the purchase, distribution, storage, and use of intravenous contrast media in all inpatient and outpatient clinical areas of the healthcare organization. Regular pharmacy monitoring of the storage and the use of these products should become routine. Pharmacists should periodically attend departmental staff meetings for units where contrast media is used to discuss the safe use of intravenous contrast media, including the inappropriate use of PBPs in such areas.

Single-dose vials and syringes. In patient care units such as radiology, cardiac catheterization labs, and operating rooms, staff should draw up doses of intravenous contrast media from single-dose vials or use prefilled single-use syringes from the pharmacy or as available from most manufacturers. Any medication remaining in the vials or syringes should be discarded immediately.

Proper use of PBPs. The contents of PBPs of intravenous contrast media (or PBPs of any medication) should only be transferred to single-dose containers or syringes in the pharmacy under a laminar flow hood or other suitable ISO Class 5 environment according to USP <797>. If the dose of contrast in a single-use vial is insufficient for one patient, a PBP could be used for a single aseptic transfer to a sterile container or syringe for one patient only. The PBP should be treated as a single-use vial—the transfer set should be disconnected and any remaining drug in the PBP should be discarded immediately after the initial removal of the patient’s individual dose.
Resources
Acute Care Main Page
Current Issue
Past Issues
Highlighted articles
Action Agendas - Free CEs
Special Error Alerts
Subscribe
Newsletter Editions
Acute Care
Community/Ambulatory
Nursing
Long Term Care
Consumer
Home | Contact UsEmployment  |   Legal Notices | Privacy Policy | Help Support ISMP
 Med-ERRS | Medication Safety Officer Society Medication Safety Officers Society | Consumer Medication Safety For consumers
ISMP Canada | ISMP Spain  | ISMP Brasil  | International Group  | Pennsylvania Patient Safety Authority

200 Lakeside Drive, Suite 200, Horsham, PA 19044, Phone: (215) 947-7797,  Fax: (215) 914-1492
© 2014 Institute for Safe Medication Practices. All rights reserved

ISMP
ISMP